MFFT 90 Minimum Film Forming Temperature Instrument

Try before you buy

Find out more

Extended warranty

Find out more

Try before you buy

Find out more

Extended warranty

Find out more

Description

Ensure your paints and coatings perform correctly.

An accurate MFFT value allows the formulation of products that cure correctly under specified application conditions.

The Rhopoint Minimum Film Forming Temperature Bar (MFFT) is used to determine the minimum film forming temperature and white point in paint and coatings such as water based coatings, polymer dispersions, synthetic latexes and emulsion.

The MFFT also tests adhesives temperature optimisation in such areas as coalescence of water-borne adhesives and minimum temperature for epoxy resin cure.

  • Determines the MFFT (minimum film forming temperature) of latex, emulsions and adhesives
  • Easy to use touch screen programme control
  • Nickel plated copper platen with an electronically imposed temperature gradient
  • Optional results printer for printing date and time stamped MFFT results
  • -10˚C to 90˚C operation

Standard model (MFFT-90) has ten temperature programs

0 1 2 3 4 5 6 7 8 9
Cold end ˚C -10 -5 0 5 15 23 33 43 53 63
Warm end ˚C 8 13 18 23 33 50 60 70 80 90

Find out more about MFFT in our article ‘What is MFFT?’

The MFFT Method

A dull, nickel-plated copper platen is cooled at one end electronically and warmed at the other end, while air or nitrogen is caused to flow over the surface as a uniform blanket. The air flow is from cold end to hot end.

To achieve the required uniformity, the air or gas is delivered via a very carefully designed sintered metal distribution block. The design is such that freezing does not take place at the inlet. For use with air, a drying system is incorporated into the housing together with a flow controller. The air dryer contains indicator crystals which are clearly visible in their transparent container. The complete air conditioning system is accessible at the side of the instrument.

Water at normal mains pressure removes the excess heat from the coolers. In environments where the ambient water temperature is high, Rhopoint offer a chiller / recirculating unit to reduce this temperature. Quick release couplings are provided. Water is normally drawn from a laboratory tap and the outlet is run to drain by gravity. Alarms, both audible and visible, protect the cooling water supply.

Temperature sensors are mounted at intervals under the surface of the platen, these are used to control the temperature of the platen in accordance with the chosen program. They are also used to indicate platen temperatures down the length of the bar. A hinged viewing cover over the platen provides thermal insulation while allowing visual inspection of the determination as it progresses.

The use of this instrument may involve hazardous materials and operational procedures. It is the responsibility of the user of this instrument to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

How does the MFFT work?

1. Select program

Touch-screen intuitive operation with in-built operating guide on-screen

2. Fill application cube with product

3. Move across platen and close perspex lid

4. Coalescence will show in about 90 minutes

5. Move cursor

6. Read the exact MFFT point from the display

Video

Specifications

Weight 53.7 kg
Dimensions 690 × 800 × 590 cm
Instrument Specifications
Conforms toASTM D 2354, ISO 2115
Platen Dimensions483mm × 235mm (L × W)
Air4 l min-1 @ 100 psig
WaterMains pressure; gravity drain
inlet temperature <15°C
Mains110–120V AC or
220–240V AC
Order CodeMFFT, -10˚C to 90˚C 230V - A1212-002
MFFT, -10˚C to 90˚C 115V - A1212-002/115
Dimensions350mm × 550mm × 610mm (H × W × D)
Weight38kg
Packed Weight53.7kg
Packed Dimensions590mm × 800mm × 690mm (H × W × D)
Commodity Code9027 8017
Accessories
Included• Water connectors
• Air connector
• Spare silica gel
• Manual
• 75μm (0.003”) cube applicator
Optional• Chiller - Required when the temperature of the water supply to the instrument is >20ºC higher than the target temperature at the cold end of the selected range.
e.g. Range 0, -10ºC requires a water supply of no higher than 10ºC. If this cannot be supplied then the chiller is required
• Label printer
Extras• Free extended warranty service
• Fast and economic service via our global network of accredited service centres, please visit www.rhopointinstruments.com/distributors/category/service-centre/ for detailed information

What’s in the box

Included:

  • Water connectors
  • Air connector
  • Spare silica gel
  • Manual
  • 75μm (0.003”) cube applicator

Optional extras

Chiller

Required when the temperature of the water supply to the instrument is >20ºC higher than the target temperature at the cold end of the selected range. e.g. Range 0, -10ºC requires a water supply of no higher than 10ºC. If this cannot be supplied then the chiller is required. View chiller

Label printer

Print off results for use on sample bottles or your records

Cube applicators

Stainless Steel 1” cube applicator, 75 & 150 micron cuts
Stainless Steel 1” cube applicator, 50 & 100 micron cuts

Please ask for these extras in your quote request

Extended 2 Year Warranty
Customer Support
Servicing

Standards & Certifications

ASTM 2354

Standard Test Method for Minimum Film Formation Temperature (MFFT) of Emulsion Vehicles

ISO 2115

Plastics — Polymer dispersions — Determination of white point temperature and minimum film-forming temperature

Applications

Paints and Coatings

The minimum film forming temperature (MFFT) of a paint or coating is the lowest temperature at which it will uniformly coalesce when laid on a substrate as a thin film. The standard test for determining this temperature involves using a MFFT-BAR, as specified by such standards as ASTM D 2354 and ISO 2115. The design of the Rhopoint instrument is based directly on these standards.

Adhesives

The MFFT of one-pack adhesives can be found in a similar way to paints and coatings. With two-pack adhesives, a strip of aluminium foil can be laid on the platen, to ease cleaning, before applying the adhesive. Two-pack adhesives do not show an MFFT, but the minimum cure temperature can be found by scraping the sample with a spatula

Answers to common questions about our instruments and measurements

Why measure gloss?

Gloss is an aspect of the visual perception of objects that is as important as colour when considering the psychological impact of products on a

Read More »

What is RSpec?

RSpec is the peak reflectance measured over a very narrow angular band in the specular direction (+/-) 0.0991º. RSpec is very sensitive to any texture

Read More »

Please email me a price confirmation and product summary

Please note, this is NOT a quotation, just a confirmation of the price when purchased in the UK exclusive of VAT/duties

Official Quote Request

Official Quote Request

MFFT 90 Minimum Film Forming Temperature Instrument